Yes, the Ignitor wire length may be tailored to your specific needs. Occasionally the wires may need to be extended. We recommend that a 20-gauge copper strand wire be used. Make sure that all splices are cleaned, secure and insulated. PerTronix offers a simple wire extension kit (part number 2005) which includes all the necessary connections.


Flame-Thrower coils are made with two different internal materials, oil and epoxy. Epoxy filled coils have a cured resin which supports the coil internal winding's and they can be mounted in any direction. Oil filled coils should always mounted upright to prevent a potential leak of critical fluid as the coil heats up and cools down.
Help Topics: General Help, Ignition General Help, Ignitor Application Inquiry


Our Ignitor and Ignitor II electronic ignition systems and Flame-Thrower distributors are compatible with most capacitive discharge boxes. Only Ignitor III electronic conversions and Ignitor III equipped Flame-Thrower distributors cannot be used with other company's CD systems. The Ignitor III can be used with our Digital HP CD box. Wiring for these Ignition boxes typically follows the instructions for point type ignitions. The red Ignitor module wire should be connected to a 12V ignition power source. The attached diagram applies to MSD 6 series ignitions.
Help Topics: Ignition General Help, Ignitor Application Inquiry


Only Ignitor systems and not the Ignitor II or III can be static timed. On negative ground applications, the easiest way to static time the distributor is to attach the clip lead of a 12 volt test light to the engine ground. Probe the coil negative terminal with the test light. The intensity of the light will be dim when the module is in a dwell state. The moment the light goes bright is the point wire the module triggers.
Help Topics: Ignition General Help, Ignitor Application Inquiry


Yes. We are constantly working on developing new kits to provide coverage in many areas. Additionally many applications we have converted are extremely rare and only done with customer supplied distributors. For more specific information regarding our custom conversions please create an application ticket with your details and one of our technicians will reply to you. Feel free to attach pictures to help us determine what options you have.
Help Topics: Ignitor Application Inquiry


PerTronix Ignitor and Ignitor II will work with many aftermarket Electronic Fuel Injected (EFI) systems. As long as the EFI system can be triggered with a square wave signal from coil negative it will work with the Ignitor or Ignitor II. Some EFI systems just call this a points signal. Some EFI system's needs a sine wave signal from something like a magnetic pick up distributor to be triggered. We also over these type distributors for many engine applications. Most all EFI system will work our Digital HP box for maximum performance. From the Digital HP box we offer a 5-volt square signal, which will trigger most EFI systems. I'm sorry the Ignitor III will not work with a EFI system because of the multiple strikes that happen on coil negative. You could add our digital HP box to allow the Ignitor III to work your EFI system. Or switch the Ignitor III to our Ignitor or Ignitor II systems.
Ignition General Help, Ignitor Application Inquiry


The Ignitor fits entirely inside the distributor, and in most cases installs quicker than points. There are no “black boxes” or complicated wiring. Simply install the kit into the distributor attach the two wires to the appropriate location, and you’re done. Some applications may require a little more work, which may add to the level of difficulty. We have some helpful installation videos of our most popular kits which can be viewed Here
Ignition General Help, Ignitor Application Inquiry

Bypassing a resistor wire isn't always the easiest job. You have to find the start point of the resistor wire and run a new 12-14 gauge wire down to coil positive. You will not need to install any fuses in this line. Depending on the application digging through the wiring harness is a pain. We have made that job easier with our Power relay. This will make bypassing the resistor wire a 10 min job. It's part number: 2001 http://shop.pertronix.com/pertronix-2001-ignition-power-relay-kit.html#.W5r5iKZKiUk
Help Topics: Ignition General Help, Ignitor Application Inquiry
Help Topics: Ignition General Help, Ignitor Application Inquiry

Label the wires attached to the coil terminals and note their appropriate location. Make sure that the ignition switch is off and disconnect all wires from the coil. Adjust your meter to the lowest ohm scale. If you are using an analog style meter make sure to zero the needle. Measure from the negative terminal to the positive terminal. Make sure that the terminals are clean.


Help Topics: Ignition General Help, Ignitor Application Inquiry

To figure this out, a quick look at the two wires on the Ignitor's is all that is needed. If you have a Red wire and Black wire, you have a negative ground Ignitor. If you have a Black wire and Black W/white tracer wire, you have a positive ground Ignitor.


Help Topics: Ignition General Help, Ignitor Application Inquiry

The following test should be performed only on negative ground applications.


Attachments: Power and Ground Checks.pdf

Only Ignitor modules can be tested with the following steps. Ignitor II and Ignitor III modules should not be tested in the same manner.

  • Negative ground modules have one red and one black wire.
  • Open the attachment below and follow the directions on it.
  • For additional support after performing these test contact the technical support line at 909-599-5955 Ext. 1

  • Attachments: Negative Ground Module Test.pdf

    Help Topics: Ignition General Help

    Only positive ground Ignitor modules can be tested with the following steps.

  • Negative ground modules have one red and one black wire.
  • Open the attachment below and follow the directions on it.
  • For additional support after performing these test contact the technical support line at 909-599-5955 Ext. 1

  • Attachments: Postive module test.pdf

    Help Topics: Ignition General Help

    Only positive ground Ignitor modules can be tested with the following steps.

    Mercedes used a transistorized ignition system for many years. The Ignitor's can completely eliminate these systems or work in conjunction with the transistorized systems. Below is a diagram that will help with wiring the Ignitor's up to the transistorized system.


    Attachments: Mercedes wiring.pdf

    Help Topics: Ignition General Help

    Special wiring is necessary with factory installed Porsche CD ignition systems. Click on the diagram below to view the proper Ignitor wiring.


    Attachments: Porsche_CD_diagram.pdf

    Help Topics: Ignition General Help

    First you want to figure out if you have a Ignitor, Ignitor II, or Ignitor III. This can be done by the label on the part.
    Ignitor label will say Ignitor;Also the Ignitor is made of black epoxy
    Ignitor II label will say Ignitor II; Also the Ignitor II is made of red epoxy. 
    Ignitor III label will say Ignitor III; Also the Ignitor III will have a small dial on top.
    Part numbers for the Ignitor kits ARE NOT found on any the labels on the Ignitor's. You should find a part number stamped on the mounting plate the ignitor is attached. If the Ignitor has more then one mounting plate check both plates for a part number. If the plate is not stamped you should find a part number on the magnet ring that is under the rotor. If the ring doesn't have a part number then normally that means we only have one option for the application. So, we just need to know the application to figure out the part number.
    Some Ignitor plates are stamped with a combination of numbers we have listed some examples below:
    Plate is stamped 1541-61. For a 4 cylinder engine will take Ignitor part number: 1541 and 6 cylinder engine will take Ignitor part number: 1561.
    Plate is stamped 1542-62. For a 4 cylinder engine will take Ignitor part number: 1542 and 6 cylinder engine will take Ignitor part number: 1562.
    Plate is stamped 1581-82. If you have a clip down distributor cap it will take part number: 1581. If you have a screw down distributor cap you will need part number: 1582


    Help Topics: Ignition General Help , Warranty

    If you can’t find your application in our Catalog / Application Guide, it does not mean that it's not available. We have many kits that have been developed for distributors and applications not listed in the Application guide. You may call our technical support line at 909-599-5955 Ext. 1 for additional help, or create an application ticket with your details and one of our technicians will reply to you. The more information you can supply about your vehicle or equipment the better.


    Help Topics: Ignitor Application Inquiry

    The Ignitor electronic ignition is far from being universal. Each kit is designed specifically for the distributor type. However, our kits will often fit many distributors from the same manufacturer. A kit that has been designed for a particular distributor type may also fit other distributors that use the same point set, cap and rotor.
    Help Topics: Ignitor Application Inquiry

    Occasionally after upgrading to electronic ignition, some tachometers experience compatibility issues. In most cases we are able to get the tachometer to function again using one of the two methods. There are two basic forms of tachometers we encounter. The first and most popular uses the coil negative signal to determine RPM. The second is wired inline with the primary ignition circuit and registers RPM off the current. For tachometers that use coil negative signal follow the attached instructions. For current registered tachs read the attached document titled Current Tachs.


    Attachments: Volvo tach Document.pdf , Tachometer fixes for 12V signal style _2_.pdf , smith tachs.pdf , Ford with factory Tach.jpg
    Help Topics: Ignitor Application Inquiry

    The first step in troubleshooting involves answering a few questions.

    • Do you have the correct kit for your application?
    • Did the Ignitor install without any modification?
    • Was the Ignitor installed according to the instructions?
    • Did the engine run prior to the installation of the Ignitor?

    If you answered "NO" to any of the previous questions, go back and correct the condition before proceeding. If the answer to these questions is “YES”, then review some additional common solutions to a no start condition.

    • The position in which the Ignitor red wire is attached to is not supplying sufficient voltage.
    • The air gap between the module and magnet sleeve is too great.
    • The ground wire inside the distributor is not connected.
    • The wire connections are not tight.
    • The polarity is not correct.

    Our line of Flame-Thrower coils are specifically designed to complement our Ignitor, Ignitor II and Ignitor III ignition systems. The chart below outlines the appropriate coil to use with each type of Ignition and the various voltages.

    image

    All PerTronix products are guaranteed to the original purchaser to be free of defects in materials and workmanship.

    ProductWarranty Period
    Ignitor®, Ignitor II, & Ignitor III30 months
    Industrial Distributor90 days mechanical / 30 months Ignitor
    Flame-Thrower® Coils90 days
    Flame-Thrower® Spark Plug WiresLifetime
    Flame-Thrower® HEI Distributors and Component PartsLimited 1 Year
    Flame-Thrower® Plug n Play Billet Distributors & "Stock Look" distributors1 Year Mechanical / 30 months on Ignitor, Ignitor IIand Ignitor III
    Second Strike™ & Digital Rev Limiter & Digital HPLimited 1 Year
    Limited WarrantyPerTronix, Inc. warrants to the original Purchaser that its products shall be free from defects in material and workmanship for a period, as specified above, from the day of purchase.Should a part become defective it should be returned to the original selling retailer and must be accompanied with the sales receipt.If there is no retailer in your area, call the factory for a return authorization number and return your part prepaid to the factory for inspection. The manufacturer reserves the right to repair or replace the alleged defective part and return the part freight collect.


    Firing order: 1,8,4,3,6,5,7,2
    Attachments: Billet Mag.pdf (130 kb) 

    Instruction sheet for D301700, D301711
    These use the same sheet

    Firing order: 1,8,4,3,6,5,7,2
    Attachments: Billet Mag.pdf (130 kb) 

    Instruction sheet for D305710, D305711, D305810, D305811
    These use the same sheet.

    Firing order: 1,8,4,3,6,5,7,2
    Attachments: D305710.pdf (133.2 kb) 

    Instruction sheet for D310710, D310711
    These use the same sheet

    Firing order: 1,8,4,3,6,5,7,2
    Attachments: Billet Mag.pdf (130 kb) 

    Instruction sheet for D320710, D320711
    These use the same sheet

    Firing order: 1,8,4,3,6,5,7,2
    Attachments: Billet Mag.pdf (130 kb) 

    Instruction sheet for D330710, D330711
    These use the same sheet

    Firing order: 1,5,4,2,6,3,7,8
    Attachments: Billet Mag.pdf (130 kb) 

    Instruction sheet for D331710, D331711
    These use the same sheet

    Firing order: 1,3,7,2,6,5,4,8
    Attachments: Billet Mag.pdf (130 kb) 

    Instruction sheet for D332710, D332711
    These use the same sheet

    Firing order: 1,3,7,2,6,5,4,8
    Attachments: Billet Mag.pdf (130 kb) 

    Instruction sheet for D333710, D333711
    These use the same sheet

    Firing order: 1,5,4,2,6,3,7,8
    Attachments: Billet Mag.pdf (130 kb) 

    Instruction sheet for D341710, D341711, D342710, D342711, D343710, D343711
    These use the same sheet

    Firing order: 1,8,4,3,6,5,7,2
    Attachments: Billet Mag.pdf (130 kb) 

    Instruction sheet for D350710, D350711
    These use the same sheet
    Attachments: Billet Mag.pdf (130 kb) 

    Instruction sheet for D351710, D351711
    These use the same sheet
    Attachments: Billet Mag.pdf (130 kb) 

    Instruction sheet for D360710, D360711
    These use the same sheet

    Firing order: 1,8,4,3,6,5,7,2
    Attachments: Billet Mag.pdf (130 kb) 

    Instruction sheet for D100700, D100701, D100710, D100711, D100800, D100801, D100810, D100811

    Chevy firing order:  1,8,4,3,6,5,7,2 In clockwise direction
    Attachments: billet.pdf (191 kb) 

    Instruction sheet for D101700, D101701, D101710, D101711, D101800, D101801, D101810, D101811,
    These all use the same sheet

    Firing Order: 1,8,4,3,6,5,7,2 In clockwise direction
    Attachments: billet.pdf (191 kb) 

    Instruction sheet for D105810, D105811
    These use the same sheet

    Chevy firing order: 1,8,4,3,6,5,7,2 In clockwise direction
    Attachments: D105811.pdf (180.6 kb) 

    Instruction sheet for D106700, D106701, D106710, D106711, D106800, D106801, D106810, D106811
    These all use the same part number

    Firing order: 1,5,3,6,2,4 In clockwise direction
    Attachments: billet.pdf (191 kb) 

    Instruction sheet for D107700, D107701, D107710, D107711, D107800, D107801, D107810, D107811
    These use the same sheet.

    Firing order: 1,6,5,4,3,2 In clockwise direction
    Attachments: billet.pdf (191 kb) 

    Instruction sheet for D110700, D110701, D110710, D110711, D110800, D110801, D110810, D110811
    These use all the same sheet

    Firing order: 1,8,4,3,6,5,7,2 In Counter Clockwise direction
    Attachments: billet.pdf (191 kb) 

    Instruction sheet for D120700, D120701, D120710, D120711, D120800, D120801, D120810, D120811
    These all use the same sheet

    Firing order: 1,8,4,3,6,5,7,2 In Counter Clockwise direction
    Attachments: billet.pdf (191 kb) 

    Instruction sheet for D130700, D130701, D130710, D130711, D130800, D130801, D130810, D130811
    All use the same instruction sheet.

    Firing order for a 221-302 ford engine: 1,5,4,2,6,3,7,8. In counter clockwise direction.
    Attachments: billet.pdf (191 kb) 

    Instruction sheet for D131700, D131701, D131710, D131711, D131800, D131801, D131810, D131811
    These all use the same sheet

    Firing order: 1,3,7,2,6,5,4,8 In Counter Clockwise direction
    Attachments: billet.pdf (191 kb) 

    Instruction sheet for D132700, D132701, D132710, D132711, D132800, D132801, D132810, D132811
    These all use the same instruction sheet

    Firing order: 1,3,7,2,6,5,4,8 In Counter Clockwise direction
    Attachments: billet.pdf (191 kb) 

    Instruction sheet for D133700, D133701, D133710, D133711, D133800, D133801, D133810, D133811
    These all use the same sheet

    Firing order: 1,5,4,2,6,3,7,8 In Counter Clockwise direction
    Attachments: billet.pdf (191 kb) 

    Instruction sheet for D141700, D141701, D141710, D141711, D141800, D141801, D141810, D141811

    Firing order: 1,8,4,3,6,5,7,2 In clockwise direction
    Attachments: billet.pdf (191 kb) 

    Instruction sheet for D142700, D142701, D142710, D142711, D142800, D142801, D142810, D142811

    Firing order: 1,8,4,3,6,5,7,2 In Counter clockwise direction
    Attachments: billet.pdf (191 kb) 

    Instruction sheet for D143700, D143701, D143710, D143711, D143800, D143801, D143810, D143811

    Firing order:1,8,4,3,6,5,7,2 In Counter Clockwise direction

    Instruction sheet D150700, D150701, D150710, D150711, D150800, D150801, D150810, D150811
    Attachments: billet.pdf (191 kb) 

    Instruction sheet D151700, D151701, D151710, D151800, D151801, D151810, D151811
    These all use the same instruction
    Attachments: billet.pdf (191 kb) 

    Instruction sheet for D160700, D160701, D160710, D160711, D160800, D160801, D160810, D160811
    These all use the same instruction sheet.


    Firing order: 1,8,4,3,6,5,7,2 In Clockwise direction
    Attachments: billet.pdf (191 kb) 

    Instruction sheet for D180811, D180810, D180813
    These all use the same sheet

    Firing order: 1,2,4,3
    Attachments: VW Billet Ignitor 2.pdf (606.5 kb) 

    Instruction sheet for D186811, D186810, D186813

    Firing order:1,2,4,3
    Attachments: VW Billet ignitor.pdf (596.4 kb) 

    Instruction sheet for D200800, D200801, D200810, D200811
    These use the same sheet

    Firing order: 1,8,4,3,6,5,7,2 In Clockwise direction

    For application with a Mercruiser add any extra parts for the shift interrupter.

    For application with a OMC shift interrupter. Please see this link:
    http://support.pertronix.com/scp/faq.php?id=7
    Attachments: billet.pdf (191 kb) 

    Instruction sheet for D206800, D206810

    Firing order: 1,5,3,6,2,4
    Attachments: billet.pdf (191 kb) 

    Instruction sheet for D207800, D2007810
    Theses use the same sheet

    Firing order: 1,6,5,4,3,2 In clockwise direction


    Attachments: billet.pdf (191 kb) 

    Instruction sheet for D209800, D209801

    Firing order: 1,2,7,5,6,3,4,8 In Clockwise direction

    For application with a Mercruiser add any extra parts for the shift interrupter.

    For application with a OMC shift interrupter. Please see this link:
    http://support.pertronix.com/scp/faq.php?id=7
    Attachments: billet.pdf (191 kb) 

    Instruction sheet for D210800, D210801
    These use the same sheet

    Firing order: 1,8,4,3,6,5,7,2
    Attachments: billet.pdf (191 kb) 

    Instruction sheet for D230800, D230801
    These use the same sheet

    Firing order: 1,5,4,2,6,3,7,8

    For application with a Mercruiser add any extra parts for the shift interrupter.

    For application with a OMC shift interrupter. Please see this link:
    http://support.pertronix.com/scp/faq.php?id=7
    Attachments: billet.pdf (191 kb) 

    Instruction sheet for D231800, D231801
    These use the same sheet

    Firing order: 1,3,7,2,6,5,4,8

    For application with a Mercruiser add any extra parts for the shift interrupter.

    For application with a OMC shift interrupter. Please see this link:
    http://support.pertronix.com/scp/faq.php?id=7
    Attachments: billet.pdf (191 kb) 

    Instruction sheet for D232800, D232801
    These use the same sheet.

    Firing order: 1,3,7,2,6,5,4,8

    For application with a Mercruiser add any extra parts for the shift interrupter.

    For application with a OMC shift interrupter. Please see this link:
    http://support.pertronix.com/scp/faq.php?id=7
    Attachments: billet.pdf (191 kb) 

    Instruction sheet for D241800, D241801

    Firing order LH rotation: 1,8,4,3,6,5,7,2 

    Firing order RH rotation: 1,2,7,5,6,3,4,8

    For application with a Mercruiser add any extra parts for the shift interrupter.

    For application with a OMC shift interrupter. Please see this link:
    http://support.pertronix.com/scp/faq.php?id=7
    Attachments: billet.pdf (191 kb) 

    Instruction sheet for D7100700, D7100701, D7100710, D7100711, D7100800, D7100801, D7100810, D7100811

    Chevy firing order: 1,8,4,3,6,5,7,2 In Clockwise direction
    Attachments: BILLET III.pdf (294.1 kb) 

    Instruction sheet for D7101700, D7101701, D7101710, D7101711, D7101800, D7101801, D7101810, D7101811

    Firing Order: 1,8,4,3,6,5,7,2 In Clockwise direction
    Attachments: BILLET III.pdf (294.1 kb) 

    Instruction sheet for D7105810, D7105811
    These use the same sheet

    Firing order: 1,8,4,3,6,5,7,2 In Clockwise direction
    Attachments: D7105811.pdf (292 kb) 

    Instruction sheet for D7110700, D7110701, D7110710, D7110711, D7110800, D7110801, D7110810, D7110811
    These all use the same sheet

    Firing order: 1,8,4,3,6,5,7,2 In Counter Clockwise direction
    Attachments: BILLET III.pdf (294.1 kb) 

    Instruction sheet for D7120700, D7120701, D7120710, D7120711, D7120800, D7120801, D7120810, D7120811
    These all use the same sheet

    Firing order: 1,8,4,3,6,5,7,2
    Attachments: BILLET III.pdf (294.1 kb) 

    Instruction sheet for D7130700, D7130701, D7130710, D7130711, D7130800, D7130801, D7130810, D7130811
    These all use the same sheet.

    Firing order: 1,5,4,2,6,3,7,8 In Counter Clockwise direction
    Attachments: BILLET III.pdf (294.1 kb) 

    Instruction sheet for D7131700, D7131701, D7131710, D7131711, D7131800, D7131801, D7131810, D7131811
    These all use the same sheet

    Firing order: 1,3,7,2,6,5,4,8 In Counter Clockwise direction
    Attachments: BILLET III.pdf (294.1 kb) 

    Instruction sheet for D7132700, D7132701, D7132710, D7132711, D7132800, D7132801, D7132810, D7132811
    These all use the same sheet

    Firing order: 1,3,7,2,6,5,4,8 In Counter Clockwise direction
    Attachments: BILLET III.pdf (294.1 kb) 

    Instruction sheet for D7133700, D7133701, D7133710, D7133711, D7133800, D7133801, D7133810, D7133811
    These use all the same sheets

    Firing order: 1,5,4,2,6,3,7,8 In Counter Clockwise direction
    Attachments: BILLET III.pdf (294.1 kb) 

    Instruction sheet for D7141700, D7141701, D7141710, D7141711, D7141800, D7141801, D7141810, D7141811
    These all use the same sheet

    Firing order: 1,8,4,3,6,5,7,2 In clockwise direction
    Attachments: BILLET III.pdf (294.1 kb) 

    Instruction sheet for D7142700, D7142701, D7142710, D7142711, D7142800, D7142801, D7142810, D7142811
    These all use the same sheet

    Firing order: 1,8,4,3,6,5,7,2 In Counter Clockwise direction
    Attachments: BILLET III.pdf (294.1 kb) 

    Instruction sheet for D7143700, D7143701, D7143710, D7143711, D7143800, D7143801, D7143810, D7143811
    These all use the same sheet

    Firing order: 1,8,4,3,6,5,7,2 In Counter Clockwise direction
    Attachments: BILLET III.pdf (294.1 kb) 

    Instruction sheet for D7150700, D7150701, D7150710, D7150711, D7150800, D7150801, D7150810, D7150811
    These use the same sheet
    Attachments: BILLET III.pdf (294.1 kb) 

    Instruction sheet for D7151700, D7151701, D7151710, D7151711,  D7151800, D7151801, D7151810, D7151811
    These use the same sheet
    Attachments: BILLET III.pdf (294.1 kb) 

    Instruction sheet D7160700, D7160701, D7160710, D7160711, D7160800, D7160801, D7160810, D7160811
    These use same sheet.

    Firing order: 1,8,4,3,6,5,7,2 This is in a Clockwise direction
    Attachments: BILLET III.pdf (294.1 kb) 

    Instruction sheet for D7180811, D7180810, D7180813
    These use the same sheet

    Firing order: 1,2,4,3
    Attachments: D7180810.pdf (332.5 kb) 

    Instruction sheet for D7200800, D7200801
    These use the same sheet

    Firing order: 1,8,4,3,6,5,7,2

    For application with a Mercruiser add any extra parts for the shift interrupter.

    For application with a OMC shift interrupter. Please see this link:
    http://support.pertronix.com/scp/faq.php?id=7

    Attachments: BILLET III.pdf (294.1 kb) 

    Instruction sheet for D7209800, D7209801

    Firing order: 1,2,7,5,6,3,4,8 In Clockwise direction

    For application with a Mercruiser add any extra parts for the shift interrupter.

    For application with a OMC shift interrupter. Please see this link:
    http://support.pertronix.com/scp/faq.php?id=7
    Attachments: BILLET III.pdf (294.1 kb) 

    Instruction sheet for D7210800, D7210801
    These use the same sheet.

    Firing order: 1,8,4,3,6,5,7,2
    Attachments: BILLET III.pdf (294.1 kb) 

    Instruction sheet for D7230800, D7230801
    These use the same sheet

    Firing order: 1,5,4,2,6,3,7,8

    For application with a Mercruiser add any extra parts for the shift interrupter.

    For application with a OMC shift interrupter. Please see this link:
    http://support.pertronix.com/scp/faq.php?id=7
    Attachments: BILLET III.pdf (294.1 kb) 

    Instruction sheet for D7231800, D7231801
    These use the same sheet

    Firing order: 1,3,7,2,6,5,4,8

    For application with a Mercruiser add any extra parts for the shift interrupter.

    For application with a OMC shift interrupter. Please see this link:
    http://support.pertronix.com/scp/faq.php?id=7
    Attachments: BILLET III.pdf (294.1 kb) 

    Instruction sheet for D7232800, D7232801
    These use the same sheet

    Firing order: 1,3,7,2,6,5,4,8

    For application with a Mercruiser add any extra parts for the shift interrupter.

    For application with a OMC shift interrupter. Please see this link:
    http://support.pertronix.com/scp/faq.php?id=7
    Attachments: BILLET III.pdf (294.1 kb) 

    Instruction sheet for D7241800, D7241801
    These use the same sheet

    Firing order LH rotation: 1,8,4,3,6,5,7,2

    Firing order RH rotation: 1,2,7,5,6,3,4,8

    For application with a Mercruiser add any extra parts for the shift interrupter.

    For application with a OMC shift interrupter. Please see this link:
    http://support.pertronix.com/scp/faq.php?id=7
    Attachments: BILLET III.pdf (294.1 kb) 

    Instruction sheet for D7190600, D7190609, D7190500, D7190509
    These use the same sheet

    Firing order: 1, 4, 3, 2 In Counter Clockwise direction

    You will also find the advance curve below
    Attachments: A&B curve.xls (73 kb)  British Cast Ig III.pdf (130.5 kb) 

    Instruction sheet for D061601

    Attachments: D061601.pdf (100.9 kb) 

    Instruction sheet for D134600, D134610, D134620, D134630
    Please see PDF below

    To adjust the vacuum advance you will need a 2.5MM or 3MM allen wrench.
    One full turn Counter Clockwise will subtract 2°. One full turn Clockwise will add 2°.
    To lockout the advance turn it Counter Clockwise until it stops

    Mechanical advance chart below. This chart is in distributor degrees, for crankshaft degrees the advance numbers will need to be doubled.

    220-302 and FE firing order: 1,5,4,2,6,3,7,8
    351W, 302 H.O. and 351C-460 firing order: 1,3,7,2,6,5,4,8
    Attachments: Cast Stock Look 8 cylinder.pdf (308.3 kb)  2012.12.11 - Ford Cast.xls (51 kb) 

    Instruction sheet for D144600

    To adjust the vacuum advance you will need a 2.5MM or 3MM allen wrench.
    One full turn Counter Clockwise will subtract 2°. One full turn Clockwise will add 2°.
    To lockout the advance turn it Counter Clockwise until it stops

    Firing order: 1,8,4,3,6,5,7,2

    Instruction sheet for D170618, D170619, D170600, D170609, D174218, D174219, D174228, D174229

    These use the same sheet

    Firing order: 1,3,4,2 In Counter Clockwise direction

    For the distributor advance curve chart below for distributors.
    Attachments: A&B curve.xls (73 kb)  British Ig II Cast.pdf (95.3 kb) 

    Instruction sheet for D171618, D171600
    These use the same sheet

    Firing order: 1,5,3,6,2,4

    Advance curve below
    Attachments: A&B curve.xls (73 kb)  British Ig II Cast.pdf (95.3 kb) 

    Instruction sheet for D173400, D173409, D172400, D172409
    These use the same sheet

    Firing order: 1,3,4,2 In Counter Clockwise direction
    Attachments: British Ig distributor Ins.pdf (95.3 kb) 

    Instruction sheet for D173401, D173419, D172401, D172419

    Firing order: 1,3,4,2
    Attachments: British Ig Pos Distributor.pdf (94.7 kb) 

    Instruction sheet for D173420, D173429, D172420, D172429
    These all use the same sheet

    Firing order: 1,3,4,2 In Counter Clockwise direction
    Attachments: British Ig II Cast.pdf (95.3 kb) 

    Instruction sheet for D175510, D175520, D174510

    Please select the correct PDF below

    Attachments: 2012.06.11 - D175510, Rover V8.xls (67.5 kb)  D175520.pdf (101.1 kb) 

    Instruction sheet for D177600, D177628
    These use same sheet

    Firing order: 1,5,3,6,2,4 In Counter Clockwise direction

    Advance curve attached below
    Attachments: British Ig distributor Ins.pdf (95.3 kb)  A&B curve.xls (73 kb) 

    Instruction sheet for D178600, D178609,

    These use the same sheet

    Firing order: 1,3,4,2

    For the distributor advance curve chart below for distributors.
    Attachments: A&B curve.xls (73 kb)  British Ig Pos Distributor.pdf (94.7 kb) 

    Instruction sheet for D179600

    Firing order: 1,5,3,6,2,4

    Advance curve below
    Attachments: A&B curve.xls (73 kb)  British Ig Pos Distributor.pdf (94.7 kb) 

    Instruction sheet for D181504, D181604
    These are the same sheet

    Firing order: 1,4,3,2 In Clockwise direction

    Advance curve attached below
    Attachments: 2013.08.19 - Bosch Cast.xls (50 kb)  VW & Alpha Cast IgII.pdf (124.6 kb) 

    Instruction sheet for D182504, D182604

    These use the same sheet

    Firing order: 1,4,3,2 In Clockwise direction

    Advance curve below
    Attachments: 2013.08.19 - Bosch Cast.xls (50 kb)  VW & Alpha Cast IgII.pdf (124.6 kb) 

    Instruction sheet for D185504, D185604
    These use the same sheet

    Firing order:1,3,4,2 In Clockwise direction

    Instruction sheet for D186504, D186604 Use VW Cast 12-volt PDF

    Instruction sheet for D189504, D189604 Use VW Cast 6-volt PDF

    Firing order: 1,4,3,2 In Clockwise direction

    Advance curve below
    Attachments: 2013.08.19 - Bosch Cast.xls (50 kb)  VW Cast Ig 6-Volt.pdf (132.3 kb) 

    Instruction sheet for D190600, D190609, D190500, D190509

    These use the same sheet

    Firing order: 1, 4, 3, 2 In Counter Clockwise direction

    You will also find the advance curve below
    Attachments: A&B curve.xls (73 kb)  British Ig II Cast.pdf (95.3 kb) 

    Instruction sheet for D192400, D192420, D7192420

    Please select the correct instruction sheet below

    Firing order: 1,3,4,2
    Attachments: D192420.pdf (97.5 kb)  D192400.pdf (97.9 kb)  D7192420.pdf (249.9 kb) 

    Instruction sheet for D196600, D196609, D196500, D196509
    These use the same sheet

    Firing order: 1, 4, 3, 2 In Counter Clockwise direction

    You will also find the advance curve below.
    Attachments: British Ig distributor Ins.pdf (95.3 kb)  British Dist advacne curve.xls (52.5 kb) 

    Instruction sheet for D21-11A, D21-12A, D21-13A, D23-02A, D33-03AM, D41-01A, D41-05A, D41-09B, D41-10B, D41-11B, D41-19A, D41-20A, D43-04B, D61-06A, D61-19B

    All our Industrial distributors use the same Instruction sheet.
    Attachments: Ind Dist.pdf (858.7 kb) 

    Instruction sheet for D7104600

    To adjust the vacuum advance you will need a 2.5MM or 3MM allen wrench.
    One full turn Counter Clockwise will subtract 2°. One full turn Clockwise will add 2°.
    To lockout the advance turn it Counter Clockwise until it stops

    Mechanical advance chart below. This chart is in distributor degrees, for crankshaft degrees the advance numbers will need to be doubled.

    Firing order: 1,8,4,3,6,5,7,2
    Attachments: 2012.12.17 - Chevy Cast.xls (50 kb)  CAST III CHEVY FORD 8 CYL.pdf (443.6 kb) 

    Instruction sheet for D7134600, D7134610, D7134620, D7134630

    To adjust the vacuum advance you will need a 2.5MM or 3MM allen wrench.
    One full turn Counter Clockwise will subtract 2°. One full turn Clockwise will add 2°.
    To lockout the advance turn it Counter Clockwise until it stops

    Mechanical advance chart below. This chart is in distributor degrees, for crankshaft degrees the advance numbers will need to be doubled.

    220-302 and FE firing order: 1,5,4,2,6,3,7,8
    351W, 302 H.O. and 351C-460 firing order: 1,3,7,2,6,5,4,8
    Attachments: 2012.12.11 - Ford Cast.xls (51 kb)  CAST III CHEVY FORD 8 CYL.pdf (451.8 kb) 

    Instruction sheet for D7144600

    To adjust the vacuum advance you will need a 2.5MM or 3MM allen wrench.
    One full turn Counter Clockwise will subtract 2°. One full turn Clockwise will add 2°.
    To lockout the advance turn it Counter Clockwise until it stops
    Attachments: CAST III CHEVY FORD 8 CYL.pdf (443.6 kb) 

    Instruction sheet for D7174218, D7174219, D7174228, D7174229, D7170618, D7170619, D7170600, D7170609

    These use the same sheet

    Firing order: 1,3,4,2 In Counter Clockwise direction

    For the distributor advance curve chart below for distributors.
    Attachments: A&B curve.xls (73 kb)  British Cast Ig III.pdf (130.5 kb) 

    Instruction sheet for D7181504, D7181604
    These use the same sheet

    Firing order:1,3,4,2 In Clockwise direction

    Advance curve for distributor is below
    Attachments: 2013.08.19 - Bosch Cast.xls (50 kb)  VW & Alpha Cast IgIII.pdf (239.3 kb) 

    Instruction sheet for D7182504, D7182604
    These use the same sheet

    Firing order: 1,4,3,2 In Clockwise direction

    Advance curve below
    Attachments: 2013.08.19 - Bosch Cast.xls (50 kb)  VW & Alpha Cast IgIII.pdf (239.3 kb) 

    Instructions sheet for D104600 

    To adjust the vacuum advance you will need a 2.5MM or 3MM allen wrench. 
    One full turn Counter Clockwise will subtract 2°. One full turn Clockwise will add 2°.
    To lockout the advance turn it Counter Clockwise until it stops

    Mechanical advance chart below. This chart is in distributor degrees, for crankshaft degrees the advance numbers will need to be doubled.

    Firing order: 1,8,4,3,6,5,7,2
    Attachments: Cast Stock Look 8 cylinder.pdf (308.3 kb)  2012.12.17 - Chevy Cast.xls (50 kb) 

    Instructions sheet for D176600, D176609, D176628,D176629, D174118, D174119, D174128, D174129
    These use the same sheet

    Firing order: 1,3,4,2 In Counter Clockwise direction

    For the distributor advance curve chart below for distributors.
    Attachments: British Ig distributor Ins.pdf (95.3 kb)  A&B curve.xls (73 kb) 

    Instruction sheet for 30721,30728,30741,30731,30738,30748
    Attachments: COP coils.pdf (71.3 kb) 

    Instruction sheet for 30821,30828,30831,30838,30841,30848
    Attachments: LS Coils.pdf (70.4 kb) 

    Instruction sheet for 40011,40001,40111,40101,40501,40511,40601,40611,40511,28010
    Attachments: Flamethrower 1.5-3.0.pdf (452.6 kb) 

    Instruction sheet for 44001, 440111
    Attachments: Flamethrower III.pdf (402.7 kb) 

    Instruction sheet for 45001, 45011, 45101, 45111
    Attachments: Flamethrower II.pdf (413.9 kb) 

    Instruction sheet for 60100
    Attachments: HP Coil.pdf (346.1 kb) 

    Part numbers: 60104, 60115, 60130 Please use the HV coil PDF

    Part number: 60103, Please use the HC coil PDF
    Attachments: HC Coil.pdf (495.8 kb)  HV Coil.pdf (282.9 kb) 

    Instruction sheet for 8501HT-1, 8501HT-8, 8502HT-1, 8502HT-8, 8503HT-1, 8503HT-8, 8561HT-1, 8561HT-8, 8562HT-1, 8562HT-8, 8563HT-1, 8563HT-8

    Attachments: CERAMIC PLUG BOOTS.pdf (226.8 kb) 

    Instruction sheet for Custom fit spark plug wire ALL Part numbers
    Attachments: Custom wire set.pdf (310.9 kb) 

    Instruction sheet for Universal Spark plug wire set ALL Part Numbers
    Attachments: Universal wire set.pdf (74.7 kb) 

    Instruction sheet for D1000, D1001, D1002, D1050, D1051, D1052, D1075

    Firing order: 1,8,4,3,6,5,7,2
    Attachments: HEI Distributor Ins.pdf (80.7 kb) 

    Instruction sheet for D1070, D1071

    Firing order: 1,8,4,3,6,5,7,2
    Attachments: HEI RACE.pdf (113.2 kb) 

    Instruction sheet for D1100, D1101, D1102

    Firing order: 1,8,4,3,6,5,7,2
    Attachments: HEI Distributor Ins.pdf (80.7 kb) 

    Instruction sheet for D1170, D1171

    Firing order: 1,8,4,3,6,5,7,2
    Attachments: HEI Race module.pdf (142.1 kb) 

    Instruction sheet for D1200, D1201, D1202

    Firing order: 1,8,4,3,6,5,7,2
    Attachments: HEI Distributor Ins.pdf (80.7 kb) 

    Instruction sheet for D1270, D1272

    Firing order: 1,8,4,3,6,5,7,2
    Attachments: HEI RACE.pdf (113.2 kb) 

    Instruction sheet for D1350, D1352

    Firing order 289-302: 1,5,4,2,6,3,7,8
    Firing order 302H.O.: 1,3,7,2,6,5,4,8
    Attachments: HEI Distributor Ins.pdf (80.7 kb) 

    Instruction sheet for: D1370, D1372

    Firing order 289-302: 1,5,4,2,6,3,7,8
    Firing order 302H.O.: 1,3,7,2,6,5,4,8

    Instruction sheet for D71000, D71001, D71002, D71050, D71051, D71052,

    Firing order: 1,8,4,3,6,5,7,2
    Attachments: HEI III DISTRIBUTOR.pdf (173.9 kb) 

    Instruction sheet for D71070, D71071

    Firing order: 1,8,4,3,6,5,7,2
    Attachments: HEI III RACE DISTRIBUTOR.pdf (170.3 kb) 

    Instruction sheet for D71100, D71101, D71102

    Firing order: 1,8,4,3,6,5,7,2
    Attachments: HEI III DISTRIBUTOR.pdf (173.9 kb) 

    Instruction sheet for D71170, D71171

    Firing order: 1,8,4,3,6,5,7,2
    Attachments: HEI III RACE DISTRIBUTOR.pdf (170.3 kb) 

    Instruction sheet for D71200, D71201, D71202

    Firing order: 1,8,4,3,6,5,7,2
    Attachments: HEI III DISTRIBUTOR.pdf (173.9 kb) 

    Instruction sheet: D71270, D71272

    Firing order: 1,8,4,3,6,5,7,2
    Attachments: HEI III RACE DISTRIBUTOR.pdf (170.3 kb) 

    Instruction sheet for D71350, D71352

    Firing order 289-302: 1,5,4,2,6,3,7,8
    Firing order 302H.O.: 1,3,7,2,6,5,4,8
    Attachments: HEI III DISTRIBUTOR.pdf (173.9 kb) 

    Instruction sheet for D71370, D71372

    Firing order 289-302: 1,5,4,2,6,3,7,8
    Firing order 302H.O.: 1,3,7,2,6,5,4,8
    Attachments: HEI III RACE DISTRIBUTOR.pdf (170.3 kb) 

    Instruction sheet for D78000, D78001, D78002, D78010, D78011, D78012
    Attachments: HEI III TUNEUP KIT.pdf (318.9 kb) 

    Instruction sheet for D78070, D78071
    Attachments: HEI III RACE TUNEUP KIT.pdf (319.2 kb) 

    Instruction sheet for D8000, D8001, D8002, D8010, D8011, D8012


    Attachments: HEI Tune Up Ins.pdf (573 kb) 

    Instruction sheet for D8070, D8071

    Instruction sheet 91141, 91164, 91181

    Here is a install video that will help
    https://www.youtube.com/watch?time_continue=4&v=nyk22-sVRhE
    Attachments: 91181.pdf (393.9 kb) 

    Instruction sheet 91142, 91143, 91149, 91161, 91169, 91182D, 91544, 91844, 91864A, 91864LA, 91884, 92844, 92846, 92862, 9LU-148, 91865, 91868, 91869, 91886, 91885, 92863, 92843, 91866, 91849, 92865, 91862, 91845, 92861, 91848
    These all use the same instruction sheet.


    Attachments: 91848.pdf (101.2 kb) 

    Instruction sheet 91144A, 91162A
    Attachments: 91144A.pdf (1 mb) 

    Instruction sheet 91145A, 91146A, 91163A
    See PDF below

    If you have a issue seating down the magnet ring or rotor isn't seating correctly. Please see the link below

    http://support.pertronix.com/scp/faq.php?id=59
    Attachments: 91146A.pdf (1 mb) 

    Instruction sheet 91168LS, 91241LS, 91762LS, 91763LS, 92163LS, 92563LS, 9LU-146LS, 9LU-241LS, 9LU-168LS, 9LU-169LS, 9MR-148LS
    These all use the same sheet
    Attachments: 9LU-146LS.pdf (153.1 kb) 

    Instruction sheet 91181LS
    Attachments: 91181LS.pdf (119.2 kb) 

    Instruction sheet 91183
    Attachments: 91183.pdf (128.3 kb) 

    Instruction sheet 91244A
    Attachments: 91244A.pdf (266.4 kb) 

    Instruction sheet 91247XT, 91247
    Please select the correct PDF for your part number
    Attachments: 91247 REVA.pdf (136.5 kb)  91247XT.pdf (139.1 kb) 

    Instruction sheet 91248A
    Attachments: 91248A.pdf (100.7 kb) 

    Instruction sheet 91261, 91266, 91281, 9AC-181, 9AC-181V, 91481, 91482, 92845, 91641, 91643, 91661, 91662, 91741, 91761, 91642, 92848, 91847A, 91941, 91942, 9HO-141, 9MR-145, 9SV-141, 91949,92847
    These all use the same sheet

    Here is a video of a 1281 install. It will help with install on 91281, 91261, 91266, 9AC-181,9AC-181V parts:
    https://www.youtube.com/watch?time_continue=3&v=tlj5KYjAVn4
    Attachments: 92848.pdf (116.7 kb) 

    Instruction sheet 91264, 91249
    These use the same sheet
    Attachments: 91264.pdf (98.1 kb) 

    Instruction sheet 91281DV
    Attachments: 91281DV.pdf (847.7 kb) 

    Instruction sheet 91282, 91283

    This video will help with install of kit into distributor:
    https://www.youtube.com/watch?v=ZfV0fS2IRN4&t=1s
    Attachments: 91282.pdf (115.7 kb) 

    Instruction sheet 91284
    Attachments: 91284.pdf (206.7 kb) 

    Instruction sheet 91286LS
    Attachments: 91286LS.pdf (572 kb) 

    Instruction sheet 91362, 91569, 92561
    These use the same instruction sheet
    Attachments: 91569.pdf (217.1 kb) 

    Instruction sheet 91382,91383,91384,91584
    Attachments: 91382.pdf (118.8 kb) 

    Instruction sheet 91385LS
    Attachments: 91385LS.pdf (103.5 kb) 

    Instruction sheet 91442, 91461
    These use the same instruction sheet
    Attachments: 91442.pdf (110.6 kb) 

    Instruction sheet 91483A, 91484A, 9HO-161A, 91485A, 9HO-142
    These all use the same instruction sheet
    Attachments: 91483A.pdf (102.3 kb) 

    Instruction sheet 91541, 91542, 91543, 91545, 91548, 91549, 91561, 91562, 91568, 91585A, 92541, 91567A
    These use all the same sheet
    Attachments: 91567A.pdf (108.3 kb) 

    Instruction sheet 91581, 91582, 91563B, 91546

    For application with a Mercruiser add any extra parts for the shift interrupter.

    For application with a OMC shift interrupter. Please see this link:
    http://support.pertronix.com/scp/faq.php?id=7
    Attachments: 91581.pdf (1 mb) 

    Instruction sheet 91589
    Attachments: 91589.pdf (230 kb) 

    Instruction sheet 91589
    Attachments: 91589.pdf (230 kb) 

    Instruction sheet 91647
    Attachments: 91647.pdf (100 kb) 

    Instruction sheet 91665A
    Attachments: 91665A.pdf (605.6 kb) 

    Instruction sheet 91762
    Attachments: 91762.pdf (98 kb) 

    Instruction sheet 91847V, 91863, 91867A, 92842, 91843
    These use the same instruction sheet
    Attachments: 91847V.pdf (101.2 kb) 

    Instruction sheet 91887LS

    Wiring unit up to factory ignition box.
    http://support.pertronix.com/scp/faq.php?id=50
    Attachments: 91887LS.pdf (67.8 kb) 

    Instruction sheet 91943
    Attachments: 91943.pdf (107.1 kb) 

    Instruction sheet 91944, 91945
    Attachments: 91944.pdf (0.9 mb) 

    Instruction sheet 91947
    Attachments: 91947.pdf (116.7 kb) 

    Instruction sheet 91948
    Attachments: 91948.pdf (117.8 kb) 

    Instruction sheet 92181, 92182, 92183
    Attachments: 92181.pdf (123.5 kb) 

    Instruction sheet 92866
    Attachments: 92866.pdf (223.9 kb) 

    Instruction sheet 9AC-182A
    Attachments: AC-182A with Ring.jpg (1 mb)  9AC-182A.pdf (113.4 kb)  AC-182A with out Ring.jpg (0.9 mb) 

    Instruction sheet 9CH-161, 9CH-181
    These use the same sheet
    Attachments: 9CH-181.pdf (0.9 mb) 

    Instruction sheet 9DU-142LS
    Attachments: 9DU-142LS.pdf (112.8 kb) 

    Instruction sheet 9HO-143
    Attachments: 9HO-143.pdf (106.9 kb) 

    Instruction sheet 9HO-181, 9HO-183
    Attachments: 9HO-183.pdf (99.5 kb) 

    Instruction sheet 9HO-182
    Attachments: 9HO-182.pdf (99.9 kb) 

    Instruction sheet 9LU-1122A
    Attachments: 9LU-1122A.pdf (251.4 kb) 

    Instruction sheet 9LU-142A 9LU-143, 9LU-144, 9LU-149, 9LU-243, 9LU-165, 9LU-162A, 9LU-244, 9LU-166A
    All these use the same Instruction sheet.
    Attachments: 9LU-165.pdf (137.5 kb) 

    Instruction sheet 9LU-145
    Attachments: 9LU-145.pdf (97.1 kb) 

    Instruction sheet 9LU-161 & 9LU-167
    Both these part numbers use the same sheet
    Attachments: 9LU-161.pdf (150.4 kb) 

    Instruction sheet 9LU-181A
    Attachments: 9LU-181A.pdf (112.8 kb) 

    Instruction sheet 9LU-263
    Attachments: 9LU-243.pdf (100.6 kb) 

    Instruction sheet 9LU-281
    Attachments: 9LU-281.pdf (324.6 kb) 

    Instruction sheet 9ML-162A, 9ML-182, 9ML-186B
    Attachments: 9ML-162A.pdf (200.4 kb) 

    Instruction sheet 9ML-181

    On marine applications only. If you have a OMC shift interrupter, please see the link below:
    http://support.pertronix.com/scp/faq.php?id=7


    Attachments: 9ML-181.pdf (165.6 kb) 

    Instruction sheet 9ML-187A
    Attachments: 9ML-187A.pdf (617.9 kb) 

    Instruction sheet 9ML-189
    Attachments: 9ML-189.pdf (116.9 kb) 

    Instruction sheet 9MR-143, 9SV-142, 9SV-161
    These all use the same instruction sheet
    Attachments: 9MR-142A.pdf (135.6 kb) 

    Instruction sheet 9MR-146
    Attachments: 9MR-146.pdf (99.8 kb) 

    Instruction sheet 9MR-161A, 9MR-1121A, 9MR-1122A
    All these use the same Instruction sheet
    Attachments: 9MR-161A.pdf (98.5 kb) 

    Instruction sheet 9MR-163
    Attachments: 9MR-163.pdf (98.8 kb) 

    Instruction sheet 9MR-182
    Attachments: 9MR-182.pdf (97.2 kb) 

    Instruction sheet 9MR-183
    Attachments: 9MR-183.pdf (305.4 kb) 

    Instruction sheet 9MR-LS1
    Attachments: 9MR-LS1.pdf (133.5 kb) 

    Instruction sheet 9RR-181, 9RR-182
    These use the same sheet
    Attachments: 9RR-181.pdf (188 kb) 

    Instruction sheet 9WO-141
    Attachments: 9WO-141.pdf (402.6 kb) 

    TERMS & CONDITIONS / WARRANTY

    PerTronix Performance ProductsWarranty

  • Ignitor®, Ignitor II, Ignitor III – 30 months
  • Industrial Distributor – 90 days mechanical / 30 months Ignitor
  • Flame-Thrower®/Compu-Fire® Coils – 90 days Flame-Thrower® Spark Plug Wires – Lifetime
  • Flame-Thrower® HEI Distributors and Component Parts – Limited 1 Year
  • Flame-Thrower® Plug n’ Play Billet and Cast Distributors –1 Year Mechanical / 30 months module
  • Second Strike® & Digital Rev Limiter – Limited 1 Year Digital HP Ignition Box – Limited 1 Year
  • Digital HP Mobile Ignition Box – Limited 1 Year Contour Automotive Starters – Limited 1 Year
  • Compu-Fire VW Ignition and Rotating Electrical – Limited 1 Year

    PerTronix Performance Products
    LIMITED WARRANTY


    PerTronix, LLC warrants to the original Purchaser that its products shall be free from defects in material and workmanship for a period, as specified above, from the day of purchase. This warranty covers the replacement/repair of the product only and does not cover the cost of removal and installation.

    Should a part become defective it should be returned to the original selling retailer and must be accompanied with the sales receipt.

    If there is no retailer in your area, call the factory for a return authorization and return your part prepaid to the factory for inspection. The manufacturer reserves the right to replace or repair the alleged defective part and return the part freight collect.

  • UPP

    PerTronix Unilateral Pricing Policy

    We have worked hard over the years to ensure the success of our distribution channel which we know must ultimately rely on the success of our resellers. We believe that it is critical to strengthen both of our positions in the markets we serve. For 2019 we will be implementing various sales and marketing programs designed to further retain and strengthen our brand values and a healthy distribution channel; most notably is the Unilateral Pricing Policy. The Unilateral Pricing Policy (UPP) sets a Minimum Retail Price (MRP) for all PerTronix Ignition, JBA Performance Exhaust, Doug’s Headers and Patriot Exhaust products. This policy is designed to curb price slashing among PerTronix Brand retailers, enabling them to remain profitable in this highly competitive business environment. To remain in good standing, PerTronix Resellers must NOT advertise or sell PerTronix branded products below the MRP.

    Thank you for visiting and shopping at PerTronix, LLC. Following are the terms and conditions that constitute our UPP Policy.

    WHY IS PerTronix, LLC. INTRODUCING A UPP?

     
    PerTronix, LLC. is introducing a new pricing policy to maintain the long-term strength of its brands, to make sure that only quality dealers carry the products and to make sure there are sufficient margins for these valuable dealers to continue to support PerTronix, LLC.

    WHAT IS THE NEW PRICING POLICY?

     
    The Unilateral Pricing Policy (UPP) establishes a Minimum Retail Price (MRP) - the price a consumer actually pays - for PerTronix products.

    WHO DOES THE POLICY AFFECT?

     
    The policy affects any merchant that sells to consumers. This includes, but is not limited to: jobbers, retailers, online dealers, warehouse distributors, auction sellers, or auction sites.

    HOW CAN IT BE VIOLATED? 

    A violation is defined as the sale or advertising of a PerTronix product(s): Below the stated MRP Which are bundled together at a price below the aggregated MRP of the individual items On a website with ambiguous pricing such as: "See Price in Cart", "Make Offer", "bid", rebate funds, customer specific funds, or "Instant Message me for pricing"

    WHAT ARE THE PENALTIES FOR VIOLATING THE POLICY? 

    Once a violation is discovered, the reseller will automatically be penalized in accordance to their first, second or third offense.

    HOW LONG WILL I BE PENALIZED FOR? 

    Duration and severity increases for each respective violation. Penalties and the full policy can be downloaded here.

    HOW DOES UPP WORK WITH MSP? 

    The UPP replaces any and all of MSP terms and conditions.

    ARE DISCONTINUED PARTS INCLUDED IN THE UPP? 

    No, all discontinued parts are excluded from Minimum Retail Pricing. Please refer to the price sheet for all part numbers that fall under the UPP.

    WHEN WILL THE NEW PRICING POLICY GO INTO EFFECT? 

    The UPP will go into effect March 1, 2019

    WHAT BRANDS DOES THE UPP OVERSEE? 

    UPP pertains only to PerTronix Performance Brands: PerTronix Ignition, JBA Performance Exhaust, Doug’s Headers and Patriot Exhaust.

    DO I SIGN THE PRICING POLICY? 

    You do NOT sign our pricing policy - this is a unilateral policy - meaning after the UPP goes into effect all dealers passively choose to accept it or not.

    IS THIS LEGAL? 

    This is legal. U.S. antitrust law states that it is lawful for manufacturers to adopt a policy regarding resale prices and to deal only with resellers that independently choose to follow the policy. Many companies in other industries have already implemented a similar program.


    Download The Pertronix UPP Here

    For any questions, please contact the PerTronix Unilateral Pricing Program Administrator.  


    Please note: No persons other than the program administrator is authorized to answer questions regarding PerTronix Unilateral Pricing Program.

    UPP PROGRAM ADMINISTRATOR 
    440 E. Arrow Hwy, San Dimas, CA 91773 
    Phone: 909-599-5955 
    Fax: 909-599-6424